APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20375 Issued:1985-02-26
Revised:2019-11-07
Style 20375 Jacketed Cable

Rating105 deg C, 300 Vac, Cable flame.
Conductor36 AWG min., solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more individually insulated conductors or groups of insulated conductors cabled together to form a round cable. A flat or oval cable may also be constructed with not more than three rows of single conductors or groups of conductors. The length of lay of the twisted conductors or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be of fibrous wrap serving, or braid; paper; nylon; oriented polyethylene terephthalate; or thermoplastic-type wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketPUR
dia diameter of cable under jacket
0.700 or less*30 mils min average24 mils minimum at any point
0.701-1.000 dian45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
*Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024