Rating | 80 deg C, 30 Vac, Horizontal Flame for Use No. 1, Cable flame for Use No. 2. |
|
Conductor | 50 AWG minimum, solid or stranded. |
|
Insulation | Material not specified for Use No. 1. |
|
Insulated Conductor | Labeled or complying with manufacturer's AWM procedure for Use No. 2. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. May use same or mixed AWG. Lay not specified. Barrier layer and/or fillers optional. |
|
Covering | Optional. Extruded PVC, 13 mils minimum at any point or PTFE tape, 1 mil minimum thickness, a helically or longitudinally applied (lap not specified). |
|
Shield | Optional. May be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | Extruded PVC. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.250 inch or less | 15 mils | 12 mils |
| 0.251-0.350 inch | 22 mils | 17 mil |
| 0.351-0.424 inch | 30 mils | 24 mils |
| 0.425-0.700 inch | 60 mils | 48 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Use No. 1 - Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors.
Use No. 2 - Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas. |
|