APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20381 Issued:1985-03-01
Revised:2012-04-12
Style 20381 Multiple-conductor cable using non-integral jacket.

Rating105 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyFlat Ribbon Cable folded or spiraled layers. Section may be slit into singles of 2 to 100 in length. Fillers optional.
ShieldOptional.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
0.700 inch or less30 mils24 mils
0.701-1.000 inch45 mils36 mils
1.001-1.500 inch60 mils48 mils
1.501-2.500 inch80 mils68 mils
2.501-4.000 inch110 mils88 mils
4.001 inch and larger140 mils112 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024