APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20387 Issued:1985-03-25
Revised:2019-11-07
Style 20387 Multiple-conductor cable using non-integral extruded jacket.

Rating105 deg C, 300 Vac, Cable flame, Oil Resis 60 or 80C, Moisture Resis 75C, 720hr Sunlight Resistance.
InsulationLabeled or complies with manufacturer's AWM Procedure having a minimum rating of 75 deg C wet, and 60 deg C or 80 deg C oil .
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use mixed sizes of insulated singles.
ShieldOptional - may be over one or more of the insulated conductors or applied over the assembly.
JacketPVC. Recognized Component - Polymeric Materials for Use in Wire and Cable (QMTT2). 720 Hour Sunlight Resistant Jacket Compounds
dia of the cable under jacket
0.700 inches or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal wiring