APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20390 Issued:1985-04-22
Revised:2012-03-21
Style 20390 Parallel Cable with Extruded Integral Insulation and Jacket

Rating105 deg C, 300 Vac.
Conductor18 AWG - 16 AWG consisting of 30 AWG or smaller stranded, tinned or bare.
InsulationExtruded TPE, integral with Jacket, 60 mils minimum average thickness, 54 mils minimum thickness at any point.
AssemblyTwo conductors, same as for Type SPE-2.See Facing Page for compound. Web thickness: 80 mils, Wall after rip: 28 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of butter conditioners where exposed at the door hinge, or internal wiring of electric refrigerators where ripped not more than three inches. Polarity identification may be omitted.