APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20396 Issued:1985-04-24
Revised:2012-04-26
Style 20396 Bonded or laminated flat ribbon cable

Rating90 deg C, 125 Vac, Horizontal flame.
Conductor48 AWG - 20 AWG bare, tinned or plated, flat conductors. Min thickness of 1.0 mils; max thickness of 6 mils. Min width of 5.0 mils; max width of 1 inch. Conductors may be straight or irregularly shaped and are in one plane.
InsulationPOLYESTER, On each side of the conductors a 1.5 mils min at any point wall of polyester film with polyester or epoxy adhesive backing. Min 3.5 mils of insulation on outside edges of strip and 4.5 mils min of insulation between adjacent conductors. Length of insulated conductors not specified.
AssemblyTwo through 200 conductors
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and appliances.