APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2040 Issued:1959-05-01
Revised:2011-09-16
Style 2040 Two-Conductor Style SPT-3 Cord.

Rating105 deg C, 600 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded, tinned or bare copper.
InsulationIntegral with Jacet. PVC, 60 mils min average, 54 mils minimum at any point.
AssemblyTwo conductor, same as SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electric Refrigerators or Room Cooler Units where ripped not more than 15 inches and where exposed to temperatures not exceeding 105 deg C. Tag may also add: where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.