Rating | 60 deg C, 60 Vac, Cable flame. |
|
Conductor | 33 AWG - 10 AWG, solid or stranded. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more individually insulated conductors or groups of insulated conductors cabled together to form a flat cable with no more than three rows of single conductors or groups of conductors. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving, or braid; paper; nylon; oriented polyethylene tereph thalate; or thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors. |
|
Jacket | Extruded PVC |
| Majar diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.700 inch or less | 30 mils | 24 mils |
| 0.701 - 1.000 inch | 45 mils | 36 mils |
| 1.001 - 1.500 inch | 60 mils | 48 mils |
| 1.501 - 2.500 inches | 80 mils | 64 mils |
| 2.501 - 4.000 inches | 110 mils | 88 mils |
| 4.001 inches and larger | 140 mils | 112 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | External and internal wiring of Class 2 wiring systems. |
|