APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20403 Issued:1985-07-26
Revised:2011-10-24
Style 20403 Multiconductor cable with extruded non-integral jacket.

Rating60 deg C, 300 Vac, Cable flame.
Conductor28 AWG - 16 AWG, solid or stranded.
InsulationExtruded PE, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
AssemblyTwo conductors; This cable consists of two insulated conductors laid parallel with an overall PVC jacket and interconnecting web.
ShieldOptional - One or two may be shielded. (This may be applied as a single or a double shield.)
CoveringOptional.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.