APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20405 Issued:1985-06-27
Revised:2012-04-17
Style 20405 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 150 Vac, Cable flame.
Conductor33 AWG - 18 AWG solid, stranded or tinsel.
InsulationExtruded TPES or extruded TPE, 7 mils min average, 5 mils minimum at any point.
AssemblyTwo to ten. Cable may be either straight or wound in retractile form. Core may be either flat or round.
ShieldOptional - One or more may be shielded.
JacketExtruded TPU, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. May also be marked "300 volts peak."
Use"Internal or Interconnecting Cable of Electronic Equipment." May also be marked "300 volts peak".

UL and the UL Logo are trademarks of UL LLC © 2024