Rating | 60 deg C, 150 Vac, Cable flame. |
|
Conductor | 33 AWG - 18 AWG solid, stranded or tinsel. |
|
Insulation | Extruded TPES or extruded TPE, 7 mils min average, 5 mils minimum at any point. |
|
Assembly | Two to ten. Cable may be either straight or wound in retractile form. Core may be either flat or round. |
|
Shield | Optional - One or more may be shielded. |
|
Jacket | Extruded TPU, 30 mils min average, 24 mils minimum at any point. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. May also be marked "300 volts peak." |
|
Use | "Internal or Interconnecting Cable of Electronic Equipment." May also be marked "300 volts peak". |
|