APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20406 Issued:1985-07-03
Revised:2012-05-22
Style 20406 Multiple-Conductor Cable using Non-Integral Jacket.

Rating80 deg C, 30 Vac, Horizontal Flame.
Inner Conductor40 AWG minimum, Solid or Stranded Round.
InsulationInner layer - Extruded foamed PE or extruded foamed XLPE. Outer layer - Extruded PE or extruded XLPE. 3 - 100 mils total composite thickness, Two layers are non-separable.
AssemblyTwo to four conductors, Insulated conductors or shielded insulated conductors may be laid parallel or twisted together to form flat or round cable. Length of lay not specified.
ShieldOptional.
Inner CoveringOptional - Extruded PVC, extruded nylon (polyamide), extruded TPE, extruded FEP, extruded PVDF, extruded ETFE or non-extruded lacquered braid, 2 mils minimum thickness at any point.
Outer ConductorOptional.
Outer CoveringOptional - Over metal braid shield, otherwise, extruded PVC, extruded nylon (polyamide), extruded FEP, extruded PVDF, extruded ETFE or lacquered braid, 2 mils minimum thickness at any pont.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring.

UL and the UL Logo are trademarks of UL LLC © 2024