APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20408 Issued:1985-08-07
Revised:2012-02-20
Style 20408 Parallel cable with extruded integral insulation and jacket

Rating105 deg C, 300 Vac, FT-2 Flame.
Conductor24 AWG - 18 AWG, stranded, consists of 30 AWG or smaller conductor strands.
InsulationExtruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyThree-conductors, same as flexible cord type SPT-1. The cable shall be formed with two 18 AWG conductors and one 22 AWG- 24 AWG conductor. The two 18 AWG conductors shall be adjacent.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseSpecial purpose cord to be used only as a power supply cord for touch control lamps.