Rating | 60 deg C, 300 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more singles, twisted pairs of groups of twisted singles twisted together or groups may be laid parallel to form flat, oval or round cable.. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Shield | Optional. |
|
Covering | Optional - A 15 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
Jacket | PUR |
| dia of cable under jacket |
| 0.700 inches or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501-4.000 dia | 110 avg | 88 min |
| 4.001 dia and larger | 140 avg | 112 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or X-Ray equipment). |
|