APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20410 Issued:1985-07-29
Revised:2019-11-07
Style 20410 Multiconductor cable with extruded non-integral jacket.

Rating60 deg C, 300 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more singles, twisted pairs of groups of twisted singles twisted together or groups may be laid parallel to form flat, oval or round cable.. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size.
ShieldOptional.
CoveringOptional - A 15 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPUR
dia of cable under jacket
0.700 inches or less30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or X-Ray equipment).

UL and the UL Logo are trademarks of UL LLC © 2024