APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20413 Issued:1985-08-08
Revised:2012-07-26
Style 20413 Multiple-Conductor Cable using Non-Integral Extruded Jacket

Rating60 deg C, 150 Vac, Cable Flame.
Conductor40 AWG - 10 AWG, Solid or Stranded Round, material not specified.
InsulationLabeled or complying with manufacturer's AWM procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form.
ShieldOptional - May be over one or more of the insulated conductors or applied over the assembly.
CoveringOptional - Extruded Polyester Elastomer, 20 mil minimum, 40 mils maximum at any point.
JacketExtruded TPU
diameter of cable under jacket in inchesmils minimum averagemils minimum at any point
1.000 or less3024
1.001-1.5004536
1.501-2.5006048
2.501-4.0008064
4.001 and larger11088
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring or External Interconnection.

UL and the UL Logo are trademarks of UL LLC © 2024