APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20419 Issued:1985-09-06
Revised:2012-03-21
Style 20419 Multiple-Conductor Cable Using Extruded Non-Integral Jacket

Rating60 deg C, 30 Vac, Cable flame.
Conductor28 AWG - 16 AWG solid or stranded round, tinned or bare.
InsulationExtruded PE, 20 mils minimum average thickness, 18 mils minimum thickness at any point.
AssemblyTwo conductors, which may be twisted or laid parallel. PE covering extruded over the conductor assembly. One or two insulated conductors may be shielded. This may be applied as a single or a double shield over the polyethylene covering.
ShieldOptional - One or two insulated conductors may be shielded. Single or double shields may be applied over the polyethylene covering.
CoveringExtruded PE, 15 mils minimum thickness at any point.
JacketExtruded PVC, 30 mils minimum average thickness, 24 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024