APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20420 Issued:2001-08-27
Revised:2017-08-01
Style 20420 Flat Cable

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG - 10 AWG material not specified.
InsulationExtruded FRPE or PE or PP or PVC or XLPVC or XLPE or XLPP, 5 mils minimum average thickness, 4 mils minimum thickness at any point, solid or cellular, irradiation optional.
AssemblyTwo or more insulated singles laid parallel, same or mixed AWG.
ShieldOptional.
CoveringOptional - Extruded PVC: 5 mils minimum thickness at any point. May have web between insulated singles. May be integral with PVC insulation when no shield employed on the PVC insulated singles.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal Wiring of Class 2 Circuits in Electronic Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024