Rating | 200, 250 deg C, 300 Vac, Horizontal flame. |
|
Conductor | 36 AWG - 14 AWG solid or stranded round. |
|
Insulation | Extruded FEP (rated max 200 deg C) or PFA, 7 mils min at any point. |
|
Assembly | Two through 150 conductors laid parallel. Sections of the cable may be split into singles or groups of conductors. |
|
Shield | Optional. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment (such as computers and electric business machines). |
|