APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20425 Issued:1985-10-07
Revised:2012-04-24
Style 20425 Flat Cable

Rating105 deg C, 150 Vac, Horizontal flame.
Conductor36 AWG - 4 AWG bare, silver plated, tin plated, nickel plated, tin plated oxygen-free copper, or silver plated copper alloy Nos. 36-4 AWG round or flat. Minimum width 20 mils, maximum width 2-1/2 inches. Minimum thickness 1 mil, maximum thickness 15 mils.
InsulationPET, PETP. On each side of the conductor 3.0 mils minimum of Oriented Polyethylene Terephthalate bonded together or 1.5 mils minimum of polyester adhesive bonded to 1.5 mils Oriented Polyethylene Terephthalate. Minimum 15 mils insulation width on outside edges of conductors and 15 mils minimum insulation width between adjacent conductors. Length of insulted conductors not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and electric business machines.

UL and the UL Logo are trademarks of UL LLC © 2025