APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20427 Issued:1985-10-16
Revised:2012-12-28
Style 20427 Multiple-conductor cable using non-integral jacket

Rating80 deg C, 30 Vac, VW-1 flame.
ConductorMinimum 40 AWG. Solid or stranded.
InsulationExtruded FRPE, PE, PVC, foamed FRPE, foamed PE, foamed PVC, XLFRPE, XLPE, XLPVC, foamed XLFRPE, foamed XLPE or foamed XLPVC, 2 mils minimum thickness at any point, 100 mils maximum thickness.
AssemblyTwo or more insulated singles may be twisted or laid parallel to form round, flat or oval cable. Barrier and/or fillers optional.
CoveringOptional. Extruded PVC, Nylon, Polyester, PVDF, ETFE or lacquered braid, 2 mils minimum thickness at any point.
ShieldOptional.
JacketExtruded PVC, 2 mils minimum thickness at any point, 40 mils maximum thickness.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseWiring of Low Energy Non-Hazardous Circuits in Audio and Video Equipment.

UL and the UL Logo are trademarks of UL LLC © 2024