APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2043 Issued:1959-05-01
Revised:2012-07-13
Style 2043 Multiple conductor with extruded insulation.

Rating90 deg C, 600 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 AWG - 16 AWG consisting of No. 30 AWG or smaller stranded.
InsulationIntegral with Jacket. PVC, 60 mils min average.
AssemblyThree conductor, same as SPT-3.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Electric Refrigerators or Room Cooler Units where ripped not more than 15 inches and where exposed to temperatures not exceeding 90 deg C. Tag may also add: where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.