			| Rating | 105 deg C, 600 Vac, Cable flame. | 
		
			 | 
		
			| Insulation | Labeled or complies with manufacturer's AWM Procedure. | 
		
			 | 
		
			| Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. | 
		
			 | 
		
			| Shield | Optional - May be over one or more of the insulated conductors or applied over the assembly. | 
		
			 | 
		
			| Jacket | Extruded TPU. | 
		
			 | Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point | 
		
			 | 0.425 inch or less | 45 mils | 36 mils | 
		
			 | 0.426-0.700 inch | 60 mils | 48 mils | 
		
			 | 0.701-1.500 inch | 80 mils | 64 mils | 
		
			 | 1.501-2.500 inch | 110 mils | 88 mils | 
		
			 | 2.501 inch and larger | 140 mils | 112 mils | 
		
			 | 
		
			| Standard | Appliance Wiring Material UL 758. | 
		
			 | 
		
			| Marking | General. | 
		
			 | 
		
			| Use | Internal or external wiring. | 
		
			 |