APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20431 Issued:1985-12-04
Revised:2012-04-09
Style 20431 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together. Barrier layer and/or fillers optional, manufacturer shall maintain a complete description of each assembly.
ShieldOptional.
CoveringOptional. Extruded PVC, 5 mils minimum thickness.
JacketExtruded SRPVC.
Dia of cable under jacketminimum average thicknessminimum thickness at any point
0.425 inch or less20 mils16 mils
0.426 - 0.700 inch30 mils24 mils
0.701 - 1.000 inch40 mils36 mils
1.001 - 1.500 inch50 mils40 mils
1.501 - 2.500 inch60 mils48 mils
2.501 inch and larger80 mils64 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external wiring.