APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20433 Issued:1986-01-06
Revised:2012-10-25
Style 20433 Multiple-conductor cable using non-integral jacket

Rating60 deg C, Voltage Not Specified, Cable flame.
Conductor36 AWG - 10 AWG solid or stranded round, tinned or bare copper.
InsulationLabeled or complying with manufacturer's AWM procedure, 3 mils min average.
AssemblyTwo or more different conductor sizes may be used in one cable. Two conductcrs may be laid parallel or twisted together. Three or more conductors or groups of insulated conductors cabled together. All conductors in any group twisted together. If more than one group is used, groups shall also be twisted together. Lay of insulated conductors not specified. Barrier layer and/or fillers optional.
ShieldOptional.
CoveringOptional - A 10 mil or heavier PVC covering may be extruded over the conductor assembly.
JacketPVC
dia of cable under jacket 0.425 inches or less30 mils min average24 mils minimum at any point
0.426-0.700 dia60 avg48 min
0.701-1.500 dia80 avg64 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseConstruction A Internal wiring of X-ray Equipment, or in the internal or external interconnection of electronic equipment. Construction B External interconnection of electronic equipment in abuse areas, such as X-ray Equipment and Business Machines.