APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20437 Issued:1986-01-30
Revised:2012-07-12
Style 20437 Multiple conductor cable using non-integral jacket

Rating80 deg C, 150 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's AWM Procedure.
AssemblyTwo through 150 conductors laid parallel. Sections of the cable may be split into singles or groups of conductors.
ShieldOptional.
CoveringOptional - Extruded PVC, 5 mils min at any point, 80 mils max.
JacketExtruded PVC
DIA of cable under jacket 0.700 inches or less30 mils min average24 mils minimum at any point
0.701-1.000 in45 avg36 min
1.001-1.500 in60 avg48 min
1.501-2.500 in80 avg64 min
2.501-4.000 in110 avg88 min
4.001 or larger140 avg112 min
Major dia if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or X-Ray Equipment).