Rating | 80 deg C, 150 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two through 150 conductors laid parallel. Sections of the cable may be split into singles or groups of conductors. |
|
Shield | Optional. |
|
Covering | Optional - Extruded PVC, 5 mils min at any point, 80 mils max. |
|
Jacket | Extruded PVC |
| DIA of cable under jacket 0.700 inches or less | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 in | 45 avg | 36 min |
| 1.001-1.500 in | 60 avg | 48 min |
| 1.501-2.500 in | 80 avg | 64 min |
| 2.501-4.000 in | 110 avg | 88 min |
| 4.001 or larger | 140 avg | 112 min |
| Major dia if cable is flat or oval. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment (such as desk-type calculators, dictating machines, or X-Ray Equipment). |
|