APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20445 Issued:1986-03-13
Revised:2019-11-07
Style 20445 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 30 Vac, Horizontal flame.
Conductor36 AWG - 16 AWG solid or stranded round, tinned or bare copper. Different conductor sizes may be used in one cord.
InsulationPVC, wall thickness may vary from 3.5 min at any point to 30 mils max or Labeled or complying with manufacturer's AWM Procedure.
AssemblyTwo to fifty conductors. Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round.
ShieldOptional.
JacketPUR
dia of cable under jacket
0.425 inches or less30 mils min average24 mils min at any point
0.426-0.700 dia45 avg36 min
0.701-1.500 dia60 avg48 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal or external wiring.

UL and the UL Logo are trademarks of UL LLC © 2024