APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20450 Issued:1986-04-28
Revised:2019-11-07
Style 20450 Multiple-conductor cable using non-integral jacket

Rating90 deg C, 30 Vac, Horizontal flame.
Conductor40 AWG min. Material not specified.
InsulationLabeled or complying with manufacturer's Procedure, or see Use statement.
AssemblyTwo or more twisted singles or groups of twisted singles twisted together or groups may be laid parallel to form flat, oval, or round cables. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly.
ShieldOptional - May be over one or more of the insulated conductors or applied over the assembly.
CoveringOptional.
JacketExtruded TPU - See facing page for compound
dia of cable under jacket
0.250 inches or less15 mils min average13 mils min at any point
0.251-0.424 dia30 avg24 min
0.425-0.700 dia45 avg36 min
0.701-1.000 dia80 avg64 min
1.001-2.500 dia110 avg88 min
2.501 dia and larger140 avg112 min
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseNo. 1A Internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. or Use No. 1B Cables using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits of electronic equipment where each end is terminated in connectors. Use No. 2A Internal wiring in Class 2 circuits of electronic equipment or external interconnection in Class 2 circuits of electronic equipment where not routed along walls, floors, or other abuse areas. or Use No. 2B Cables using 30 mils or greater jacket thickness only: External interconnection or internal wiring in Class 2 circuits of electronic equipment.