APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20455 Issued:1986-04-28
Revised:2012-04-23
Style 20455 Multiple-conductor cable using non-integral jacket.

Rating200 deg C, 125 Vac, Horizontal flame.
Conductor30 AWG - 22 AWG, solid or stranded.
SeparatorOptional - Foamed PTFE tape.
InsulationExtruded PTFE, 4 mils minimum thickness at any point and/or Labeled or complies with Manufacturer's AWM Procedure.
AssemblyTwo to eighty conductors laid parallel and in one plane. Adjacent ground conductor may touch. One to six conductor groups may be laid parallel and placed on top of each other.
Inner Barrier LayerOptional - Foamed PTFE tape.
ShieldOptional.
Outer Barrier LayerOptional - Foamed PTFE tape.
CoveringOptional.
JacketExtruded FEP, 10 mils minimum average thickness, 8 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring.