APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20456 Issued:1986-04-28
Revised:2012-04-26
Style 20456 Flat Ribbon Cable

Rating200 deg C, 125 Vac, Horizontal flame.
Conductor32 AWG - 22 AWG solid or stranded.
InsulationExtruded PTFE, 4 mils min average, 4 mils min at any point and/or Labeled or complies with Manufacturer's AWM Procedure.
AssemblyTwo through eighty conductors laid parallel and in one plane. Adjacent ground conductor may touch. One to six conductor groups may be laid parallel and placed on top of each other.
Barrier LayerOptional - Expanded PTFE tape
ShieldOptional.
Barrier LayerOptional - Expanded PTFE tape
CoveringExpanded PTFE braid.
Misc.Separator - Optional, Expanded PTFE Tape.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2025