Rating | 200 deg C, 125 Vac, Horizontal flame. |
|
Conductor | 32 AWG - 22 AWG solid or stranded. |
|
Insulation | Extruded PTFE, 4 mils min average, 4 mils min at any point and/or Labeled or complies with Manufacturer's AWM Procedure. |
|
Assembly | Two through eighty conductors laid parallel and in one plane. Adjacent ground conductor may touch. One to six conductor groups may be laid parallel and placed on top of each other. |
|
Barrier Layer | Optional - Expanded PTFE tape |
|
Shield | Optional. |
|
Barrier Layer | Optional - Expanded PTFE tape |
|
Covering | Expanded PTFE braid. |
|
Misc. | Separator - Optional, Expanded PTFE Tape. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|