APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 2046 Issued:1959-05-01
Revised:2012-04-16
Style 2046 Paralell cable with extruded integral insulation and jacket

Rating80 deg C, 300 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional).
Conductor18 AWG consisting of No. 30 AWG or smaller stranded.
InsulationIntegral with Jacket. Extruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point.
AssemblyTwo conductor, same as SPT-1.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 80 deg C. Dependent upon the compound used, the tag may add the statement: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted.

UL and the UL Logo are trademarks of UL LLC © 2024