Rating | 80 deg C, 300 Vac, FT-2 flame, Oil Resistant 60 deg C or 80 deg C (optional). |
|
Conductor | 18 AWG consisting of No. 30 AWG or smaller stranded. |
|
Insulation | Integral with Jacket. Extruded PVC, 30 mils minimum average thickness, 27 mils minimum thickness at any point. |
|
Assembly | Two conductor, same as SPT-1. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet, and where exposed to temperatures not exceeding 80 deg C. Dependent upon the compound used, the tag may add the statement: and where exposed to oil at a temperature not exceeding (60 deg C or 80 deg C, whichever is applicable). Polarity identification may be omitted. |
|