APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20463 Issued:1986-05-06
Revised:2012-07-22
Style 20463 Multiple-conductor cable using non-integral jacket

Rating60 deg C, 125 Vac, Horizontal flame, Gasoline Resistant.
Conductor28 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPE, 10 mils min average, 9 mils minimum at any point.
ShieldOptional - may be applied over the polyethylene covering or insulated conductors.
CoveringInner covering - 15 mil min at any point of polyethylene covering extruded over the conductor assembly, which may be twisted or parallel conductors; Outer covering - Extruded nylon in 5 mil min thickness, employing Recognized Component QMTT2 nylon for Gasoline Resistance.
JacketPVC, 15 mils min average, 12 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances or electronic equipment where exposed to temperatures not exceeding 60 deg C in dry location and in liquid gasoline and gasoline vapor at ordinary ambient.