APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20464 Issued:1986-06-06
Revised:2022-05-06
Style 20464 Multiple-conductor cable using non-integral jacket

Rating60, 75, 80, 90, 105 deg C, 30, 90 150 Vac, Horizontal flame.
Conductor40 AWG - 10 AWG solid or stranded.
InsulationLabeled or complying with the manufacturer's AWM Procedure.
AssemblyTwo or more individually insulated wires or groups or individually insulated wires forming a round, oval or flat cable. The length of lay of the twisted wires or groups is not specified. Fillers may be used in a cable but are not required. A barrier layer, if employed, may be a fibrous wrap serving or braid; paper; nylon; oriented polyethylene terephthalate; or a thermoplastic-tape wrap. Such a barrier layer would serve to protect the cable during further processing and would be applied immediately over the twisted assembly of individual conductors or groups of conductors.
ShieldOptional.
JacketPVC
dia of cable under jacket
0.350 inches or less*15 mils min average12 mils minimum at any point
0.351-0.700 dia30 avg24 min
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
*Major dia. if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment and appliances.

UL and the UL Logo are trademarks of UL LLC © 2024