| Rating | 150 deg C, 150 Vac, Horizontal Flame. |
|
| Conductor | 36 AWG - 16 AWG, solid or stranded. |
|
| Insulation | Extruded and heat laminated FEP, 9 mils minimum average thickness, 7 mils minimum thickness at any point. |
|
| Assembly | 2-150 conductors are laid parallel with minimum spacing between conductors of 25 mils. |
|
| Shield | Optional. |
|
| Covering | Optional - Extruded FEP, 5 mils minimum thickness at any point, 80 mils max. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. May be additionally marked "For 300 V peak electronic use only." |
|
| Use | Internal wiring of appliances or electronic equipment. |
|