APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20467 Issued:1986-05-19
Revised:2012-03-27
Style 20467 Bonded or laminated flat ribbon cable

Rating150 deg C, 150 Vac, Horizontal Flame.
Conductor36 AWG - 16 AWG, solid or stranded.
InsulationExtruded and heat laminated FEP, 9 mils minimum average thickness, 7 mils minimum thickness at any point.
Assembly2-150 conductors are laid parallel with minimum spacing between conductors of 25 mils.
ShieldOptional.
CoveringOptional - Extruded FEP, 5 mils minimum thickness at any point, 80 mils max.
StandardAppliance Wiring Material UL 758.
MarkingGeneral. May be additionally marked "For 300 V peak electronic use only."
UseInternal wiring of appliances or electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024