This Style Page is no longer being updated. It is for historic reference only. Please visit: Search - Appliance Wiring Material - Company - Product iQ for the latest Style Page information 
Subj.758 Section 2 Page 20469 Issued:1986-05-21
Revised:2012-03-22
Style 20469 Multiconductor cable with extruded non-integral jacket.

Rating80 deg C, 30 Vac, Horizontal flame.
Conductor50 AWG minimum . Material and stranding not specified.
InsulationFEP, 2 mils min average, minimum average is not specified.
AssemblyTwo through seven conductors. Insulated singles or groups of insulated singles cabled together, lay is not specified. Fillers or barrier layer is optional. Two or three insulated singles may be laid parallel.
ShieldOptional.
JacketPVC, 3 mils minimum at any point, minimum average is not specified.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of Class 2 circuits in electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2026