APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20470 Issued:1986-05-30
Revised:2019-11-07
Style 20470 Multiple-conductor cable using non-integral jacket

Rating105 deg C, 150 Vac, Cable flame.
InsulationLabeled or complying with manufacturer's Procedure.
AssemblyFlat ribbon cable folded or spiraled layers. Sections may be slit into singles of two to 100 in length. Fillers optional.
ShieldOptional.
JacketPVC
dia of cable under jacket
0.700 inches or less*30 mils min average24 mils minimum at any point
0.701-1.000 dia45 avg36 min
1.001-1.500 dia60 avg48 min
1.501-2.500 dia80 avg64 min
2.501-4.000 dia110 avg88 min
4.001 dia and larger140 avg112 min
*Major diameter if cable is flat or oval.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring or external interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024