| Rating | 105 deg C, 150 Vac, Cable flame. |
|
| Insulation | Labeled or complying with manufacturer's Procedure. |
|
| Assembly | Flat ribbon cable folded or spiraled layers. Sections may be slit into singles of two to 100 in length. Fillers optional. |
|
| Shield | Optional. |
|
| Jacket | PVC |
| dia of cable under jacket |
| 0.700 inches or less* | 30 mils min average | 24 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| 1.501-2.500 dia | 80 avg | 64 min |
| 2.501-4.000 dia | 110 avg | 88 min |
| 4.001 dia and larger | 140 avg | 112 min |
| *Major diameter if cable is flat or oval. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring or external interconnection of electronic equipment. |
|