Rating | 60 deg C, 300 Vac, Cable flame. |
|
Conductor | 40 AWG min - Material not specified. |
|
Insulation | Labeled or complying with manufacturer's AWM procedure. |
|
Assembly | Two or more twisted singles or groups of twisted singles twisted together. Lay not specified. Barrier layer and or fillers optional. Manufacturer shall maintain a complete description of each assembly. Cable may be either straight or wound in retractile form. |
|
Shield | Optional - may be over one or more of the insulated conductors or applied over the assembly. |
|
Jacket | PUR |
| dia of cable under jacket |
| 1.000 inches or less | 30 mils min average | 24 mils minimum at any point |
| 1.001-1.500 dia | 45 avg | 36 min |
| 1.501-2.500 dia | 60 avg | 48 min |
| 2.501-4.000 dia | 80 avg | 64 min |
| 4.001 dia and larger | 110 avg | 88 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or External Wiring. |
|