APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20476 Issued:1986-06-13
Revised:2012-07-29
Style 20476 Multiple-conductor cable using non-integral jacket

Rating200 deg C, 300 Vac, Horizontal flame.
Conductor16 AWG solid or stranded round, tinned or bare. Conductive Core - Over the conductor is an extruded semiconductive high temperature thermoplastic.
InsulationFEP, 13 mils min average, 12 mils minimum at any point.
AssemblyTwo conductors laid parallel and is built with a conductive core, insulation, monitor wire (optional), shield (optional),and jacket (optional). Monitor Wire - Optional. Recognized AWM single conductor style, laid parallel to insulated cable.
ShieldOptional.
CoveringOptional.
JacketOptional - FEP, 13 mils min average, 10 mils minimum at any point of FEP over insulated cable and monitor wire assembly.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024