APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20477 Issued:1986-06-17
Revised:2012-04-26
Style 20477 Multiple-conductor cable using non-integral jacket.

Rating60 deg C, 30 Vac, Horizontal flame.
InsulationLabeled or complying with this manufacturer's AWM Procedure.
AssemblyTwo or more insulated singles or groups of insulated singles cabled together. Barrier layer and/or fillers optional. Maximum diameter of conductor assembly is 1.0 inch. Maximum width of Cable is 10.0 inches.
CoveringOptional - Extruded PVC, 5 mils min, may be extruded over the conductor assembly, or extruded PTFE, extruded PFA, extruded FEP or extruded ETFE, 8 mils min. average, 6 mils minimum at any point.
ShieldOptional.
JacketExtruded PVC
Dia of cable under jacket in inchesMinimum average thickness milsMinimum thickness at any point mils
0.700 inches or less3023
0.701-1.0006048
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring and external interconnection in Class 2 circuits of electronic cable.

UL and the UL Logo are trademarks of UL LLC © 2024