Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Insulated Conductor | Labeled or complies with manufacturer's AWM Procedure. |
|
Assembly | Two or more insulated singles or groups of insulated singles cabled together. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. Twisted singles, with or without covering and shield, laid in parallel. Maximum diameter of conductor assembly is 1.0 inch. Maximum width of cable is 10.0 inches. |
|
Shield | Optional. |
|
Covering | Optional - extruded PVC, 5 mils minimum thickness; or extruded PTFE, PFA, FEP, or ETFE, 8 mils minimum average thickness, 6 mils minimum thickness at any point applied over the conductor assembly. |
|
Jacket | Extruded PVC |
| Diameter of core assembly under jacket (inches) before and after ripping | Minimum average thickness (mils) | Minimum thickness at any point (mils) |
| 0.700 inches or less | 30 avg | 23 min |
| 0.701-1.000 | 60 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring and external interconnection in Class 2 circuits of electronic equipment. |
|