APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20480 Issued:1986-06-17
Revised:2012-03-21
Style 20480 Parallel Cable with Extruded Non-Integral Jacket

Rating80 deg C, 300 Vac, Horizontal flame.
ConductorSolid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure, 6 mils minimum average thickness.
AssemblyTwo or more singles, or groups of insulated singles twisted together. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. Twisted singles, with or without covering and shield, laid in parallel. Maximum diameter of conductor assembly, 1.0 inch, maximum width of cable, 10.0 inches.
ShieldOptional.
CoveringOptional - A 10 mil thick or heavier PVC covering may be extruded over the conductor assembly.
JacketExtruded PVC
Thickness before ripping
Major Diameter of Cable in inchesAverage minimum thickness in milsMinimum thickness at any point in mils
0.700 inches or less3024
0.701-1.0004536
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of external interconnection of electronic equipment (such as desk-type calculators dictating machines, or X-Ray equipment).

UL and the UL Logo are trademarks of UL LLC © 2024