Rating | 60 deg C, 30 Vac, Cable flame. |
|
Insulation | Labeled or complying with manufacturer's AWM Procedure. |
|
Assembly | Two or more singles, twisted pairs or groups of twisted singles cabled together or groups may be laid parallel to form flat, oval or round cable. Lay not specified. Barrier layer and/or fillers optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
|
Covering | Optional, extruded PVC, 10 mils minimum thickness at any point, over the conductor assembly. |
|
Shield | Optional. |
|
Jacket | Extruded SRPVC. |
| Diameter of cable under jacket | Minimum average thickness | Minimum thickness at any point |
| 0.425 inches | 25 mils | 20 mils |
| 0.426-0.700 inch | 30 mils | 24 mils |
| 0.701-1.000 inch | 40 mils | 36 mils |
| 1.001-1.500 inch | 50 mils | 40 mils |
| 1.501-2.500 inch | 60 mils | 48 mils |
| 2.501 inch and larger | 80 mils | 64 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring or external interconnection of electronic equipment. |
|