APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20487 Issued:1986-07-16
Revised:2011-11-14
Style 20487 Multiple-conductor cable using non-integral jacket

Rating105 deg C, voltage not specified, Horizontal flame for Construction A; Cable flame for construction B.
Conductor30 AWG - 18 AWG.
InsulationExtruded ETFE, extruded PFA or extruded FEP, 9 mils minimum average thickness, 8 mils minimum thickness at any point.
ShieldOptional.
AssemblyConsists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional.
JacketExtruded ETFE. For if the diameter of cable under jacket is 0.500 inches or less for Construction A, 18 mils min average, 16 mils minimum at any point, Construction B: 25 avg, 22 min.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseConstruction A: Internal wiring of electronic equipment. Construction B: External interconnect or internal wiring of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024