APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20488 Issued:1986-07-22
Revised:2012-01-17
Style 20488 Bonded or laminated flat ribbon cable

Rating80 deg C, 300 Vac, Horizontal flame.
Conductor32-16 AWG, solid or stranded.
InsulationLabeled Styles 1007, 1061, or 1095.
AssemblyTwo to 100 insulated singles or twisted pair or triads laid parallel in one plane, retained by heat or film melt bonded section at random intervals from 2 to 100 in. apart, with or without PVC bands on one side of the cables in between the heat or film melt bonded sections. Width of heat or film melt bonded sections minimum 1 in. width of PVC bands, approx 3/16 in. Manufacturer shall maintain a record of all singles used in each cable.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of appliances, electronic computers or business equipment.