Rating | 80 deg C, 300 Vac, Horizontal flame, 60 or 80 deg C Oil. Optional - Oil Resistant. |
|
Conductor | 18 AWG, consisting of 30 AWG or smaller strands. |
|
Integral insulation and jacket | Extruded PVC, 28 mils minimum average thickness, 25 mils minimum thickness at any point. |
|
Assembly | Three conductors, same as SPT-1 except for a nominal 80 mils separation distance between insulated conductors, 70 mils minimum web thickness and 28 mils minimum after ripped insulation thickness. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electric refrigerators where installed within separate metal enclosures or between walls of the cabinet. Dependent upon the compound used, the tag may add the statement. Polarity identification may be omitted. |
|