Rating | 105 deg C, 150 Vac, Cable flame. |
|
Conductor | 36 AWG - 10 AWG, solid or stranded. |
|
Assembly | Consists of a max of six flat cables labeled or complying with the manufacturer's AWM Procedure. Fillers or tapes optional. |
|
Shield | Optional or expanded metallic ground planes, one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh construction. |
|
Jacket | Extruded PVC. |
| Diameter of core assembly under jacket | Minimum average thickness | Minimum thickness at any point |
| 2.500 inches or less for four or more cables | 15 mils | 12 mils |
| 2.501-3.500 inches for four or more cables | 20 mils | 16 mils |
| 3.500 inches or less for three or less cables | 15 mils | 13 mils |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring in Class 2 or 3 circuits only of electronic equipment. |
|