APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20492 Issued:1986-08-26
Revised:2012-04-16
Style 20492 Multiple-conducto cable using non-integral jaclet

Rating105 deg C, 150 Vac, Cable flame.
Conductor36 AWG - 10 AWG, solid or stranded.
AssemblyConsists of a max of six flat cables labeled or complying with the manufacturer's AWM Procedure. Fillers or tapes optional.
ShieldOptional or expanded metallic ground planes, one or both sides. The ground plane may be flat copper or aluminum and may be employed as a solid or mesh construction.
JacketExtruded PVC.
Diameter of core assembly under jacketMinimum average thicknessMinimum thickness at any point
2.500 inches or less for four or more cables15 mils12 mils
2.501-3.500 inches for four or more cables20 mils16 mils
3.500 inches or less for three or less cables15 mils13 mils
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring in Class 2 or 3 circuits only of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024