APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20500 Issued:1986-10-22
Revised:2012-01-27
Style 20500 Multiple-conductor cable using non-integral jacket

Rating105 deg C, Voltage Not Specified, Horizontal Flame.
Conductor36 AWG min., solid or stranded.
InsulationLabeled or complying with manufacturer's AWM procedure
AssemblyTwo or more insulated singles or groups of twisted insulated singles twisted together. Length of lay not specified. Barrier layer and or fillers are optional. Manufacturer shall maintain a complete description of each assembly. Maximum core diameter is 0.500 inches.
ShieldOptional.
JacketExtruded FEP, PFA or ETFE. 12 mils minimum average thickness, 10 mils minimum thickness at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseInternal wiring of electronic equipment.