Rating | 80 deg C, 30 Vac, Cable flame. |
|
Conductor | 36 AWG - 22 AWG solid or stranded round. |
|
Insulation | Extruded PTFE, Extruded TFE, 3 mils minimum average thickness, 2 mils minimum thickness at any point; or flat cable complying with Manufacturer's AWM Procedure. |
|
Assembly | Two through eighty conductors laid parallel and in one plane. Adjacent ground conductors may touch. Optional, Two to six conductor groups may be laid parallel on top of each other. Insulation is built with a separator (optional), insulate, inner barrier layer (optional), shield (optional) and outer barrier layer (optional). |
|
Shield | Optional. |
|
Covering | Inner layer (optional), expanded PTFE or polyester tape between insulated conductors and shield. Outer barrier (optional), expanded PTFE or polyester tape. |
|
Braid | Optional. |
|
Jacket | Extruded PUR, 15 mils minimum average thickness, 12 mils minimum thickness at any point. |
|
Misc. | Separator, over conductor - Optional, Expanded PTFE tape. |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of electronic equipment. |
|