Rating | 60 deg C, 30 Vac, Horizontal flame. |
|
Conductor | 36 AWG - 16 AWG solid or stranded. Different conductor sizes may be used in one cord. |
|
Insulation | Extruded PP, wall thickness may vary from 3.5 minimum thicknes at any point to 30 mils maximum thickness, or Labeled or complies with manufacturer's AWM procedure. |
|
Assembly | Two to fifty conductors; Cable may be either straight or wound in retractile form. Core may be either flat (max 20 conductors) or round. Manufacturer shall maintain a complete description of each assembly. |
|
Shield | Optional. |
|
Jacket | Extruded TPU |
| dia cable under jacket |
| 0.425 inches or less | 30 mils min average | 24 mils min at any point |
| 0.426-0.700 dia | 45 avg | 36 min |
| 0.701-1.500 dia | 60 avg | 48 min |
|
Standard | Appliance Wiring Material UL 758. |
|
Marking | General. |
|
Use | Internal wiring of appliances or electronic equipment. |
|