|
| Rating | 80 deg C, 90 Vac, Cable flame. |
|
| Conductor | 40 AWG minimum. Material not specified. |
|
| Insulation | PVC or SRPVC or XLPVC, 7 mils min average, 5 mils minimum at any point. |
|
| Assembly | Consists of two or more conductors, twisted pairs or groups of twisted conductors twisted together. The conductors or groups of conductors may be laid parallel forming a flat, oval or round cable. The lay of the conductors is not specified. A barrier layer and/or fillers are optional. May use same or mixed AWG size. |
|
| Covering | Optional - A 10 mil or heavier PVC covering may be extruded over the conductor assembly. |
|
| Shield | Optional. |
|
| Jacket | PVC |
| dia of cable under jacket is 0.700 inches or less | 30 mils min average | 23 mils minimum at any point |
| 0.701-1.000 dia | 45 avg | 36 min |
| 1.001-1.500 dia | 60 avg | 48 min |
| - Major diam if cable is flat or oval. |
|
| Standard | Appliance Wiring Material UL 758. |
|
| Marking | General. |
|
| Use | Internal wiring and external interconnection inClass 2 circuits of electronic equipment. |
|