APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20516 Issued:1987-02-11
Revised:2012-04-24
Style 20516 Jacketed Cable

Rating80 deg C, 300 Vac, Cable flame.
Conductor30 AWG - 16 AWG solid or stranded round, tinned or bare copper.
InsulationPE, 13 mils min average, 12 mils minimum at any point.
AssemblyTwo conductors
ShieldOptional.
Covering10 mils minimum at any point of polyethylene covering extruded over the conductor assembly, which may be twisted or parallel conductors.
JacketPVC, 30 mils min average, 24 mils minimum at any point.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UseExternal interconnection of electronic equipment.

UL and the UL Logo are trademarks of UL LLC © 2024