APPLIANCE WIRING MATERIAL
Subj.758 Section 2 Page 20519 Issued:1987-02-27
Revised:2012-05-02
Style 20519 Multiple conductor with extruded insulation

Rating125 deg C, 600 Vac, Horizontal flame.
Conductor22-16 AWG, stranded.
InsulationExtruded TPE or PVDF, 27 mils minimum thickness at any point. Extruded FEP, 20 mils minimum thickness at any point.
AssemblyTwo to three conductors; Insulation is built with a conductive core, insulation, optional shield, and optional jacket.
ShieldOptional.
JacketOptional. Extruded FEP, PVDF or TPE, 20 mils minimum thickness at any point.
Misc.Conductive Core - Over the conductor is an extruded semi-conductive high temperature thermoplastic or thermoset.
StandardAppliance Wiring Material UL 758.
MarkingGeneral.
UsePipe heating cable where the acceptability of the combination is to be determined by Underwriters Laboratories Inc.

UL and the UL Logo are trademarks of UL LLC © 2024